6-7
Cleaning the optics
Optics include the imaging guides, camera glass covers and 
sensors
. All of the optics components should be cleaned at the same 
time.
NOTE: The lamps are not part of the optics. The lamps (LEDs) should 
not be cleaned with wipes or solvents.
Cleaning the imaging guides and camera glass covers
To prevent streaks in images, reduced OCR/ICR/Barcode recognition 
rates, blurred images, etc., you should clean the imaging guides every 
50,000 pages. 
The two imaging guides which are inside black, plastic frames are 
located in the top and bottom transport trays. When removing an 
imaging guide for cleaning or replacement, the entire assembly 
(imaging guide and frame) are removed and replaced as one piece. 
Clean the camera glass covers at the same time you clean the imaging 
guides.
CAUTION: Do not remove the imaging guide from the black frame.
1. Open the scanner cover.
2. Gently pull the 2 fastening clips that secure the top imaging guide 
towards the front of the scanner to release and remove the imaging 
guide from the transport.
3. Using a Staticide wipe, clean both sides of the imaging guide. Be 
careful not to touch the cleaned glass.
IMPORTANT:Staticide wipes contain isopropanol which can cause 
eye irritation and dry skin. Wash your hands with soap 
and water after performing maintenance procedures. 
Refer to the Material Data Safety Sheet (MSDS) for 
more information. The MSDS is available on the 
Kodak web site at www.kodak.com/go/MSDS.
 Fastening clips (2)