Problem solving
Occasionally you may encounter a situation with your scanner where it 
may not function properly. Use the chart below as a guide to check 
possible solutions to help you resolve the situation before calling 
Technical Support. If a problem persists after reviewing the problems 
and possible solutions below, turn the scanner off, unplug the power 
cord and call Technical Support.
Symptom
Cause
Remedy
Installation/Setup/Connectivity
Found New Hardware wizard 
appears when connecting with 
USB on a PC that has already had 
communication established with 
the scanner.
The USB cable was unplugged 
from one port on the host PC to 
another after communication had 
been established with the scanner 
using the original port.
Move the USB cable back to the 
original port on the host PC or 
complete the Found New 
Hardware wizard.
Kofax errors displayed on host PC 
when attempting to install and use 
the USB connection with a SCSI 
card installed.
Presence of the SCSI card 
conflicting with the USB function.
Uninstall the SCSI card from the 
host PC.
Error Message
Possible Cause
Possible Remedy
Self Test Error Messages
Feeder Table Fault
The stack of documents in the 
feeder table is too heavy.
Remove some of the document 
weight from the feeder table and 
power cycle the scanner.
Internal Communication Fault
The control processor has lost 
communication with one or more of 
the following: imprinters, sensor 
processor or the control panel.
Cycle power to the scanner. If the 
problem persists, contact 
Technical Support.
Bad or Missing Front Camera
The front (top) camera is not 
communicating.
Cycle power to the scanner. If the 
problem persists, contact 
Technical Support.
Bad or Missing Back Camera
The back (bottom) camera is not 
communicating.
Cycle power to the scanner. If the 
problem persists, contact 
Technical Support.
Front and/or Back Imprinter Self 
Test Failed
An imprinter was detected and 
enabled, but is no longer 
communicating.
Check that the cable is firmly 
connected and not damaged. 
Sensor Fault
One or more sensors could not be 
calibrated.
Check that paper was not left in the 
transport at power on, and that the 
sensors are clean and not blocked. 
See Chapter 6, Maintenance.
Bad or Missing Control Panel 
(Front Panel)
The scanner’s control panel is not 
communicating.
Cycle power to the scanner. If the 
problem persists, contact 
Technical Support.