Configuration 2: R7r (+CMS) <—ethernet—> R7csi 
97
Administration for Network Connectivity
555-233-504 — Issue 1 — April 2000
CID: 77730
3  
C-LAN Administration
Worksheet B: LAN Data for the Lucent Intuity System
Complete the information on this worksheet to administer the Lucent I
NTUITY
 system 
for integration with the switch.
Field
Recommended
Your Entry
Lucent I
NTUITY
 System Switch Interface Administration Window
Extension Length
Use the extension length from the switch dial 
plan
4
Host Switch Number
Use 
1
 if the integration supports only one 
DEFINITY switch. If more than one 
DEFINITY system will be supported, use the 
number administered on the Local Node 
Number field in the host switch dial plan.
1
AUDIX Number
The number assigned to the Lucent I
NTUITY
 
system on the DEFINITY ECS. For r-model 
switches, a number from 
1
 to 
8
; for csi and si
1
. This must match the Machine-ID field of the 
Processor Channels screen.
1
Switch Number
Enter the node number of the switch being 
administered. If there is only one switch, 
the value must be 1. This must match the 
Local Node Number field in the switch dial 
plan.
1
IP Address/Host Name
Enter the IP address for the switch being 
administered.
192.168.1.124
TCP Port
Enter a TCP port number for each Intuity 
AUDIX for each switch being administered. 
This must match the Interface Channel field of 
the Processor Channels screen. You should use 
5002
 for every switch linked over the LAN in 
a DCS network. Use the numbers
6001-6999
 
for gateway TCP links to remote switches in a 
DCS network. 
5002