Справочник Пользователя для Lucent Technologies Release 8.2

Скачать
Страница из 524
Configuration 3: R8si<—x.25 —> R8r Gateway 
<—ethernet—> R8si 
3  
C-LAN Administration
Administration for Network Connectivity
CID: 77730
555-233-504 — Issue 1 — April 2000
102
Switch 1 Task — Assign pdm Data Module
This task administers a pdm data module for the connection between the PGATE 
board and the DS1 board for the connection to node-2. The data module associates a 
link number with a port address and extension number for the PGATE port used for 
this connection.
Begin
Steps
> Open the Data Module form — enter  
a da n
> Enter values
add data-module next
Page 1 of 2
Data Module
Data Extension: 30 
Name: pdm on port 1c0102
BCC:
Type: pdm_________ COS: 
Remote Loop-Around Test? n
Port: 01C0102 COR: 
Secondary data module? n
ITC: restricted__ TN: 
Connected to: dte
ABBREVIATED DIALING
List1: 
SPECIAL DIALING OPTION: 
ASSIGNED MEMBER (Station with a data extension button for this data module)
Ext Name
1: 1002 
station name
Field
Conditions/Comments
Type:
This indicates the data-module type for this connection.
Port:
This example means that the PGATE circuit pack is in 
slot 01c01 and link 5 uses port 02. 
ITC:
Enter restricted. (unrestricted is used only for 
wideband transmission.)
Name:
Information-only; appears in list generated by the “list 
data module” command.
COS:
The values for these fields will be specified by the 
system administrator.
COR:
TN:
Remote Loop-Around 
Test?
Set to 
n
 unless testing.
1 of 2