168
Switch 3 Task — Assign Processor Channels
This task associates data links with processor channels on Switch 3.
Begin
Steps
>
Open the Processor Channel Assignment form — enter
ch com p
> Enter values
change communications-interface processor-channels
Page 1 of X
Page 1 of X
PROCESSOR CHANNEL ASSIGNMENT
Proc Gtwy Interface Destination Session Mach
Chan Enable Appl. To Mode Link/Chan Node Port Local/Remote ID
1:
Chan Enable Appl. To Mode Link/Chan Node Port Local/Remote ID
1:
n
_______
_ __ _____ _________ 0____ ___ ___ __
2:
n
_______
_ __ _____ _________ 0____ ___ ___ __
:
31: y
31: y
dcs ___
c 1_ 0
__ node-1-eth 5003_ 31_
13__ 1_
32: y
dcs ___
s
1_ 5003_ node-2___ 0
32_ 23_ 2_
64: n
_______
_ __ _____ _________ 0____ ___ ___ __
Field
Conditions/Comments
Processor Channel 31
: (ethernet connection to Switch 1)
Enable
Set to
y
.
Appl.
Set to
dcs
for DCS signaling.
Mode
Node-3 is the “client” for this session. Set node-1-eth to
“server” (
“server” (
s
).
Interface Link
This must match the link number assigned on the node-3 data
module screen.
module screen.
Interface Chan
A value of
0
allows any available interface channel to be used
for this connection. The Destination Port number on the
Switch-1 Processor Channel screen must also be set to
Switch-1 Processor Channel screen must also be set to
0
.
Destination
Node
Node
Name of the far-end node for this channel. This must be a name
entered on the Node Names screen.
entered on the Node Names screen.
Destination
Port
Port
This number must match the Interface Channel number assigned
on the Switch-1 Processor Channel screen.
on the Switch-1 Processor Channel screen.
1 of 2