Configuration 5B: R8csi <—ppp—> R8r (2 C-LANs) 
<—ethernet—> R8si 
3  
C-LAN Administration
Administration for Network Connectivity
CID: 77730
555-233-504 — Issue 1 — April 2000
182
Switch 1 Task — Assign Link via ppp Data Module to C-LAN(b)
This task administers a ppp data module on Switch 1 for the ppp connection from the 
C-LAN(a) circuit pack to the C-LAN(b) circuit pack. 
Begin
Steps
Open Data Module form — enter 
ad da 2013
> Enter values
add data-module 2013 
                                                                 Page 1 of x
                          DATA MODULE
    Data Extension: 2013 
Name: _ppp on link 12 to clan(b)__ BCC: 2
              Type: ppp
    
COS: 1
              Port: 01c0713 COR: 
1
              Link: 12 TN: 
1
       Enable Link? n
         Node Name: node-1a
_____
Subnet Mask: 255.255.255.0 
Establish Connection: y
DESTINATION
            Digits: 2378___________
      Node Name: node-1b___________
              CHAP? n
Field
Conditions/Comments
Type:
This indicates the data-module type for this link.
Port:
In this example, the C-LAN(a) circuit pack is in slot 
01a07; the ppp connection is through port 13.
Link:
The link number must be in the range 1 – 33 (for R8r), not 
previously assigned on this switch.
Enable Link?
If you need to add an IP route that uses this node as a 
gateway, this field must be set to 
y
 before adding the IP 
route. Otherwise leave this field set to 
n
 until the link 
administration is complete; that is, until after all data 
modules and the processor channels are assigned, then set 
to 
y
.
Name:
Information-only; appears in list generated by the “list 
data module” command.
BCC:
Bearer Capability Class. This is a display-only field.
1 of 2