Configuration 5B: R8csi <—ppp—> R8r (2 C-LANs) 
<—ethernet—> R8si 
199
Administration for Network Connectivity
555-233-504 — Issue 1 — April 2000
CID: 77730
3  
C-LAN Administration
Switch 3 Task — Assign Link via ethernet Data Module to the LAN
This task administers an ethernet data module on Switch 3 for the ethernet connection 
to Switch 1. The data module associates a link number with a port address, extension 
number, and node name for the C-LAN port used for this connection.
Begin
Steps
> Open Data Module form — enter  
a da n
> Enter values
> Submit the screen
End
add data next 
                                                                   Page 1 of X
                        
 DATA MODULE
    Data Extension: 3901 
Name: ethernet on link 1
 
BCC: 2
              Type: ethernet
              Port: 01a0517_
              Link: 1 
Network uses 1’s for broadcast addresses? y
Field
Conditions/Comments
Type:
This indicates the data-module type for this connection.
Port:
Ethernet connections must be assigned to port 17 on the 
C-LAN circuit pack.
Link:
The link number must be in the range 1 – 25 (for R8si), not 
previously assigned on this switch.
Name:
Information-only; appears in list generated by the "list data 
module" command.
Network uses 1’s 
for broadcast 
addresses?
Leave the default (
y
) if the private network contains only 
DEFINITY switches and adjuncts. Set to 
n
 only if the 
network includes non-DEFINITY switches that use the 0’s 
method of forming broadcast addresses. See Appendix A, 
“Data Module - type ethernet” for more information about 
this field.