Switch-Node 1 Administration 
4  
Networking Example
Administration for Network Connectivity
CID: 77730
555-233-504 — Issue 1 — April 2000
208
Switch-Node 1 Administration
This section displays the filled-in screens for the administration of Switch Node 1.
DS1 Circuit Packs
Connection to Switch 
Node 2
Connection to Switch 
Node 3
add ds1 1c19
 Page   1 of   2 
                                DS1 CIRCUIT PACK                                
            Location: 01c19 
Name: Switch 1 to Switch 2 
            Bit Rate: 1.544                    Line Coding: b8zs     
   Line Compensation: 1                       Framing Mode: esf
      Signaling Mode: common-chan
Interface Companding: mulaw
           Idle Code: 11111111
             DMI-BOS? n
      Slip Detection? n                 Near-end CSU Type: other     
add ds1 1c18
 Page   1 of   2 
                                DS1 CIRCUIT PACK                                
            Location: 01c18 
Name: Switch 1 to Switch 3 
            Bit Rate: 1.544                    Line Coding: b8zs     
   Line Compensation: 1                       Framing Mode: esf
      Signaling Mode: isdn-pri
Connect: pbx ____
Interface: network
 Country 
Protocol: 
1
Protocol Version: a
Interface Companding: mulaw 
 CRC? 
n
           Idle Code: 11111111
DCP/Analog Bearer Capability: 3.1kHz
      Slip Detection? n                 Near-end CSU Type: other