Справочник Пользователя для Lucent Technologies Release 8.2
Networking Screens
A
Screens Reference
Administration for Network Connectivity
CID: 77730
555-233-504 — Issue 1 — April 2000
272
Data Module - type
pdm (used for BX.25 connections with the
r model)
This form applies only to the r model.
This form assigns a Modular Processor Data Module (MPDM) data module (700D,
7400B, 7400D or 8400B). The MPDM is an external hardware device that provides a
Data Communications Equipment (DCE) interface for connection to equipment such
as data terminals, CDR output devices, on-premises administration terminal, Message
Server, Property Management System (PMS), AUDIX, and host computers. It also
provides a Digital Communications Protocol (DCP) interface to the digital switch.
7400B, 7400D or 8400B). The MPDM is an external hardware device that provides a
Data Communications Equipment (DCE) interface for connection to equipment such
as data terminals, CDR output devices, on-premises administration terminal, Message
Server, Property Management System (PMS), AUDIX, and host computers. It also
provides a Digital Communications Protocol (DCP) interface to the digital switch.
Use the tdm data module type to assign an MTDM, which provides an EIA Data
Terminal Equipment (DTE) interface for connection to off-premises private line trunk
facilities or a switched telecommunications network and a DCP interface for
connection to the digital switch.
Terminal Equipment (DTE) interface for connection to off-premises private line trunk
facilities or a switched telecommunications network and a DCP interface for
connection to the digital switch.
Common Fields
See
for descriptions of fields on this screen that
are not listed below.
Secondary data module
Specifies whether this PDM is the primary or secondary data module.
Page 1 of 1
DATA MODULE
Data Extension: 30
Name: 27
BCC:
Type: pdm_________ COS: 1
Remote Loop-Around Test? n
Port: _______
COR: 1
Secondary data module? n
ITC: restricted__
TN: 1
Connected to: dte
ABBREVIATED DIALING
List1:
SPECIAL DIALING OPTION:
ASSIGNED MEMBER (Station with a data extension button for this data module)
Ext Name
1: 1002
27 character station name
Valid Value
Usage
y/n
Enter y if this PDM is the secondary data module used for
Dual I-channel AUDIX networking. Enter n if this is the
primary PDM, or if this data module is not used for AUDIX
networking. The primary data module must be administered
before the secondary data module may be added. If Port is
X, this field must be set to n.
Dual I-channel AUDIX networking. Enter n if this is the
primary PDM, or if this data module is not used for AUDIX
networking. The primary data module must be administered
before the secondary data module may be added. If Port is
X, this field must be set to n.