Networking Screens 
277
Administration for Network Connectivity
555-233-504 — Issue 1 — April 2000
CID: 77730
A  
Screens Reference
Circuit Packs
This screen administers circuit packs to carrier slots before the circuit packs are 
actually installed in the carrier or cabinet. This allows the system to be configured 
(administered) when the circuit packs have not yet been physically inserted in their 
appropriate slots. Before any voice terminals, attendant consoles, or trunks can be 
administered in the system, the correct type of circuit pack must be installed in the 
appropriate slot, or using the Circuit Pack screen, a circuit pack must be assigned to 
the slot.
The Circuit Pack Administration screens do not have to be completed if the system 
cabinet is equipped with the circuit packs at the time of administration. However, for 
switch node carriers, these screens must be administered.
Note:
For initial installation procedures, circuit packs should only be assigned 
slots per the hardware Configuration Layout record (obtained from the 
factory or Customer Services Support Organization). Arbitrarily 
assigning circuit packs to slots should not be attempted because this 
eventually requires (at the time of installation and test) realignment of the 
circuit packs and reworking associated wiring to agree with the software 
translations or new software translations to agree with the shipped 
hardware configuration.
Note:
Each page of the screen represents one carrier within the cabinet 
specified on the command line. For G3si, all carriers and slots appear 
even if they are not included in the actual hardware. This supports 
reconfiguration.
Cabinet
This field shows the cabinet number as entered on the command line.
                                                                   Page 1 of X
                                CIRCUIT PACKS
          Cabinet: __                           Carrier: _
   Cabinet Layout: ____________________    Carrier Type: _________________
   Slot Code   Sf Mode Name 
Slot Code  Sf Mode Name
    00: ______ _ 
11: MEDPRO _ 
RESERVED-IP
    01: ______ _ 
12: MEDPRO _ 
RESERVED-IP
    02: ______ _ 
13: TN802_ B 
MAPD
    03: ______ _ 
14: ______ _ 
    04: ______ _ 
15: ______ _ 
    05: ______ _ 
16: ______ _ 
    06: ______ _ 
17: ______ _ 
    07: ______ _ 
18: ______ _ 
    08: ______ _ 
19: ______ _ 
    09: ______ _ 
20: ______ _ 
    10: ______ _ 
21: ______ _ 
    ’#’ indicates circuit pack conflict.
Valid entries
Usage
Display-only field.