Справочник Пользователя для Lucent Technologies Release 8.2

Скачать
Страница из 524
H.323 Trunk Administration 
2  
H.323 Trunks
Administration for Network Connectivity
CID: 77730
555-233-504 — Issue 1 — April 2000
42
Task 3 — Assign Link via ethernet Data Module to the LAN  
This task administers an ethernet data module for the connection between the C-LAN 
board’s ethernet port (port 17) and the LAN. The data module associates a link 
number and extension number with the C-LAN ethernet port location. This 
association is used by the DEFINITY processor to set up and maintain signaling 
connections for multimedia call handling.
The C-LAN ethernet port is indirectly associated with the C-LAN IP address via the 
slot location (which is part of the port location) on the IP Interfaces screen and the 
node name, which is on both the IP Interfaces and Node Names screens.
Begin
Task 3 Steps
> Open Data Module form — enter  
a da n
> Enter values
> Submit the screen
End
add data-module next 
Page 1 of X
DATA MODULE
    Data Extension: 2377 
Name: ethernet on link 2
Type: ethernet
              Port: 01c0817_
              Link: 2 
Network uses 1’s for broadcast addresses?: y
Field
Conditions/Comments
Type:
This indicates the data-module type (ethernet) for this link.
Port:
Ethernet connections must be assigned to port 17 on the C-LAN 
circuit pack.
Link:
The link number must be in the range 1 – 33 for G3r, or 1 – 25 for 
G3si and G3csi, and not previously assigned on this switch.
Name:
This field is information-only; it appears in lists generated by the 
“list data module” command.
Network 
uses 1’s for 
broadcast 
addresses?
Leave the default (
y
) if the private network contains only 
DEFINITY switches and adjuncts. Set to 
n
 only if the network 
includes non-DEFINITY switches that use the 0’s method of 
forming broadcast addresses. See Appendix A, “Data Module - 
type ethernet” for more information about this field.