Справочник Пользователя для Barco SJ/T 11363-2006

Скачать
Страница из 202
142
PDS  •  User’s Guide
_K==oÉãçíÉ=`çåíêçä
Remote Commands
Parameters
:  
-i (input): 5-6 (PDS-701) 5-8 (PDS-901 and PDS-902)
-t (EDID type): 0 - analog, 1 - digital  (Default: 1)
Query Format
:  EDIDTYPE -i(input) -?
Query Response
:  EDIDTYPE -i(input) -t (EDID type) --min 0 --max 1
List Format
:  EDIDTYPE -i(input)
List Response
:
0:"Analog"
1:"Digital"
cobbwb
Description
:  Freezes the input on program. 
Command Format
:  FREEZE  -m (mode)
Parameters
:  -m (mode): 0-off, 1-on  (Default: off)
Query Format
:  FREEZE -?
Query Response
:  FREEZE -m (mode) --min 0 --max 1
f^ag
Description
:  Selects the input path to be adjusted (preview or program). This 
command is valid only for the PDS-902.
Command Format
:  IADJ -p (path)
Parameters
:-p (path): 0-preview, 1-program 
Query Format
: IADJ -?
Query Response
:  IADJ -p (path)
List Format
:  IADJ --list
List Response
:
0: "Preview"
1: "Program"
f^agopq
Description
: Reset the input timing parameters to default values for analog. This 
command is only available for analog input types.
Command Format
: IADJRST -i (input)
Parameters
: -i (input): 1 - 6 (PDS-701); 1 - 8 (PDS-901/902) 
                                    (5 - 8 only if type is analog) 
Query Format
: N/A
Query Response
: N/A
f^o=
Description
:  Adjust Input Aspect Ratio