BE DISCONTINIED
Item
                                High Sensitive Type
                                   Standard (Gold-overlay silver-nickel)      -P type (Gold-overlay silver-palladium)
Contact
Arrangement
2 form C (DPDT)
          Material
   Gold-overlay silver-nickel
        Gold-overlay silver-palladium
Style
Bifurcated
Resistance (initial)
Maximum 100 m
Ω
 (at 0.1 A 6 VDC)
Rating (resistive)
0.3 A 125 VAC or 1 A 30 VDC
Maximum Carrying Current
2 A (at 20
°
C)
Maximum Switching Power
62.5 VA or 30 W
Max. Switching Voltage*
1
250 VAC or 220 VDC
Maximum Switching Current
2 A
Minimum Switching Load*
2
10m VDC - 10
µ
 A
Capacitance
Approximately 1.0 pF  (between open contacts, adjacent contacts )
(at 10 kHz)                                Approximately1.0 pF  (between coil and contacts)
Coil
Nominal power (at 20
°
C)
Approximately 50mW
Operate power (at 20
°
C)
Approximately 40m W
Operating Temperature
–40
°
C to +70
°
C (no frost) (refer to the CHARACTERISTIC DATA)
Operating Humidity
45 to 85%RH
Time Value
Operate (at nominal voltage)
Maximum 5 msec.
Release (at nominal voltage)
Maximum 5 msec.
Insulation
Resistance (initial)
Minimum 1000 M
Ω
  (at 500 VDC)
Dielectric   between open contacts
750 VAC
Strength
    adjacent contacts
1 minute
              between coil and contacts
1,500 VAC 1 minutes
Surge         between open
1,500 V
Strength     contacts,
10 
× 
700 
µ
s
                  
adjacent contacts
              between coil and contacts
2,500 V
× 
10 
µ
s
  Life
Mechanical
    1 x 10
8
 operations minimum
Electrical                       DC
×
 10
5
 operations minimum                5 
×
 10
5
 operations minimum
(at contact rating)
                       AC
×
 10
5
 operations minimum
   200 
×
 10
3
 operations minimum
Other
Vibration        Misoperation
10 to 55 Hz (double amplitude of 3.3` mm)
Resistance
       Endurance
10 to 55 Hz (double amplitude of 5.0 mm)
Shock
       Misoperation
500 m/s
2
 (11
±
1
 ms)
Resistance
       Endurance
1,000 m/s
2
 ( 6 
±
1
 ms)
Weight
Approx. 1.9 g
■ 
SPECIFICATIONS
*
1
 If the switching voltage exceeds the rated contact voltage, reduce the current. The current values vary according to the
type of load.
*
2
 Values when switching a resistive load at normal room temperature and humidity and in a clean environment.
    The minimum switching load varies with the switching frequency and operation environment.