Справочник Пользователя для DELL N3000

Скачать
Страница из 1460
442
Monitoring Switch Traffic
rmon alarm 
number 
variable interval 
{absolute |deltarising-
threshold 
value 
[
event-
number
]
 
rising-
threshold 
value 
[
event-
number
] [startup 
direction
] [owner 
string
]
Add an alarm entry
number
 — The alarm index. (Range: 1–65535)
variable
 — A fully qualified SNMP object identifier that 
resolves to a particular instance of an MIB object.
interval
 — The interval in seconds over which the data is 
sampled and compared with the rising and falling 
thresholds. (Range: 1–4294967295)
• rising-threshold 
value
 — Rising threshold value. (Range: 
0–4294967295)
• rising-threshold 
value
 — Falling threshold value. 
(Range: 0–4294967295)
• event-number — The index of the event that is used 
when a rising or falling threshold is crossed. (Range: 1- 
65535)
• delta — The sampling method for the selected variable 
and calculating the value to be compared against the 
thresholds.  If the method is delta, the selected variable 
value at the last sample is subtracted from the current 
value, and the difference compared with the thresholds.
• absolute — The sampling method for the selected 
variable and calculating the value to be compared against 
the thresholds. If the method is absolute, the value of the 
selected variable is compared directly with the thresholds 
at the end of the sampling interval. 
• startup 
direction
 — The type of startup alarm, which can 
be risingfalling, or rising-falling.
• owner
 string
 — Enter a name that specifies who 
configured this alarm.
interface 
interface
Enter Interface Configuration mode for the specified port 
or LAG.
Command
Purpose