Справочник Пользователя для Citizen Systems CLP-8301

Скачать
Страница из 75
Chapter 6    Configuring Your Printer Using the Menus   
48
 
  
 
-
 
6.8  Menu Mode Description 
Group Menu 
Menu Item 
Default Value 
Range of Values 
Description 
Label Width 
8.53in 
216.7mm 
3.00 
- 8.64in 
76.2 
- 219.5mm 
Set print label width. 
 
Print Speed 
04 IPS 
02 
- 04 IPS 
¾ 
Print Darkness 
10 
00 
- 30* 
*When language is DDP-N3, the 
maximum value is 20. 
* Page Setup 
Print Method 
TT 
DT / Direct Thermal 
TT / Thermal Transfer 
Set printing method. 
 Ribbon 
Torque 
 
3 1 
- 5 
Set ribbon winding torque 
 Continu. 
MediaLen 
10.00in 
254.0mm 
0.25 
- 40.00in 
6.4 
- 1016.0mm 
Set print label length 
 
Vertical Position 
0.00in 
0.00mm 
- 1.00 
- 1.00in 
-25.4 
- 25.4mm 
Adjust print start position. 
 
 
Horizont Shift 
10.00in 
254.0mm 
- 1.00 
- 1.00in 
-25.4 
- 25.4mm 
Adjust left-to-right position in dots. 
Media Sensor 
See Thru 
See Thru 
Notch 
Reflect White 
Reflect Blue 
None 
Select label sensor. 
See Thru: Transparent GAP sensor. 
Notch: Transparent HOLE sensor. 
Reflect White: Reflective White base 
sensor. 
Reflect Blue: Reflective Blue base 
sensor. 
None: No use of sensor (continuous 
paper) 
Sensor Monitor 
¾ 
x.xV adc 
Monitor media sensor sensing level. 
When None, See Thru (GAP) sensor 
sensing level is monitored. 
Sensor Level 
1.5V/1.7V 
0.0V 
- 3.3V 
Set sensor threshold. 
 
Top Form 
Yes 
Yes 
No 
Select Top-Of-Form (TOF) sensing. 
Printer will feed to top-of-form before 
first print after power on. 
 
Buzzer Select 
Exec/Err 
Exec/Err 
All 
Error 
Key 
None 
Select condition for buzzer. 
Exec/Err: Sounds when setting and 
execution are completed or error 
occurs. 
All: Sounds in all situations. 
Error: Sounds only in error. 
Key: Sounds in key operation. 
None: No sound. 
 
Metric/Inch Inch  Inch 
mm 
Set basic unit of measurement to 
millimeters or inches. 
Print Res. DPI 
(Print Res. DPmm) 
300 
 
300DPI(12 DPmm) 
150DPI(6 DPmm) 
Set print resolution. 
Values in parentheses are in metric 
system. 
AutoCal Mode 
 
 
Perform sensor calibration. 
*  System Setup 
MaxMedia Length 
10.00in 
250.0mm 
1.00 
- 50.00in 
25.4mm 
- 1270.0mm 
Set GAP length. 
(continued)