Справочник Пользователя для Acer P1266i

Скачать
Страница из 126
3-5
Confidential
P1166 / P1266 / P1266i / P1166P / P1266P
No
Symptom
Procedure
Remote Control / 
Control Panel 
Failed
- Remote Control
  a. Check Battery
  b. Check Remote Control
  c. IR Receiver
- Control Panel
  a. Check FPC
  b. Check Keypad
  c. Check Main Board
3
Function 
Abnormal
- Do “Reset” of the OSD Menu
- Check Main Board
- Check DMD Board
4
WLAN & LAN Fail 
(only for P1266i)
- Ensure you have set up the right IP address and the   
  connection is OK (network LED should be light up)
- Check the Antenna
- Check the Wireless Module
- Check the Main Board