Using the Mail Notification Function to Report 
Problems
When  you  set  Mail  Notification,  notification  messages  are  sent  to  the  preset
email  addresses  when  a  problem  or  warning  occurs  with  a  projector.  This
will  enable  the  operator  to  be  notified  of  problems  with  projectors  even  at
locations  away  from  the  projectors.
s
  Network   -   Administrator  Settings   -   Mail  Notification  
a
• Up to a maximum of three notification destinations (addresses)  can
be  registered,  and  notification  messages  can  be  sent  to  all  three
destinations  at  once.
• If  a  projector  develops  a  critical  problem  and  suddenly  stops
working,  it  may  not  be  able  to  send  a  message  notifying  an  operator
of  the  problem.
• If  you set  Standby  Mode  to  Communication  On,  you  can  control
the   projector   even   if   it   is   in   standby   mode   (when   the   power   is
off).
s
  Extended   -   Standby  Mode  
Reading  Error  Notification  Mail
When  the  Mail  Notification  function  is  set  to  On  and  a  problem  or  warning
occurs  in  the  projector,  the  following  email  will  be  sent.
Mail  sender:  Address  for  Address  1
Subject:  EPSON  Projector
Line  1:  The  projector  name  where  the  problem  has  occurred
Line  2:  The  IP  address  set  for  the  projector  where  the  problem  has
occurred.
Line  3  and  on:  Details  of  the  problem
The  details  of  the  problem  are  listed  line  by  line.  The  main  message
contents  are  listed  below.
• Clean  Air  Filter  (Air  Filter  Notice)
• Internal  error
• Fan  related  error
• Sensor  error
• Lamp  cover  is  open.  (Lamp  Cover  Open)
• Lamp  timer  failure
• Lamp  out
• Internal  temperature  error
• High-speed  cooling  in  progress
• Lamp  replacement  notification
• Low   Air   Flow   (Low   Air   Flow)
• Low  Air  Flow  Error  (Filter  Airflow  Error)
• No-signal
No  Signal  is  input  to  the  projector.  Check  the  connection  status  or  check
that  the  power  for  the  signal  source  is  turned  on.
• Auto  Iris  Error
• Power  Err.  (Ballast)
See  the  following  to  deal  with  problems  or  warnings.
s
Monitoring and Controlling