Справочник Пользователя для Huawei MC509

Скачать
Страница из 156
 
HUAWEI MC509 CDMA LGA Module 
AT Command Interface Specification 
GPS Commands 
 
Issue 01 (2011-08-26) 
Huawei Proprietary and Confidential 
Copyright © Huawei Technologies Co., Ltd. 
137 
 
14.3 ^WPDFRCommand for Setting Fix Rate 
14.3.1 Syntax 
Command 
Possible Response(s) 
^WPDFR=<num>,<ti
me> 
<CR><LF>OK<CR><LF> 
Error: 
<CR><LF>+CME ERROR: <err><CR><LF> 
^WPDFR? 
<CR><LF>^WPDFR:<num>,<time><CR><LF> 
<CR><LF>OK<CR><LF> 
^WPDFR=? 
<CR><LF>^WPDFR: (list of supported <num>,<time>s) 
<CR><LF> 
<CR><LF>OK<CR><LF> 
 
14.3.2 Interface Description 
This command is used to set the fix rate of position session. READ command queries 
the current fix rate, TEST command returns supported fix rates. SET command can 
only be used before position session beginning or after 
end, can‟t be used during 
positioning, or will be error. 
 
 
this command can only use when the session type is tracking fix. 
 
14.3.3 Parameter Description 
<num >: the number of position fixes an application will trigger. The range is 1 to 
65535, default value is 65535, no storing at power down   
<time>: the valid time between fixes. This value is valid for num fixes >1. The range 
is 1 to 1800(s), default value is 1, no storing at power down   
<err>: error code or error description 
Error code 
Error description 
Operation not supported 
281 
Invalid parameter 
283 
PD session is ongoing 
285 
Too many parameters