1
–255: Automatic answer is enabled. An incoming call will be answered after the 
number of rings set by <value>
7.8 ^ORIGCommand for Indicating the Origination of a 
Call 
7.8.1 Syntax 
Command 
Possible Response(s) 
 
<CR><LF>^ORIG:<call_x>,<call_type><CR><LF> 
 
7.8.2 Interface Description 
This command indicates that the MT is originating a call. 
7.8.3 Parameter Description 
<call_x>: Specifies the call ID, uniquely identifying the call. The value ranges from 1 
to 9. 
<call_type>: Specifies the call type. The values are as follows: 
0: voice call 
2: PS domain data call (not supported at present) 
3: CDMA SMS call (not supported at present) 
7: OTA call (standard OTASP numbers) 
8: OTA call (non-standard OTASP numbers) 
9: emergency call 
7.9 ^CONNCommand for Indicating a Call Connection 
7.9.1 Syntax 
Command 
Possible Response(s) 
 
<CR><LF>^CONN:<call_x>,<call_type><CR><LF> 
 
7.9.2 Interface Description 
If the MT is the caller, when a call request is successfully sent to the network and a 
response from the network is received, the MT reports the response to the TE even