5.3 Part Names and Settings
 
5
PREPARATORY PROCEDURES BEFORE 
OPERATION
5.3
Part Names and Settings
This chapter describes the part names and settings of the local module.
Figure 5.2 Outside drawing of local module
Table 5.2 Part names and settings
No.
Name
Description
1)
LED
Name
Status
Description
RUN
ON
Data link normal
SD
Data sending
RD
Data receiving
F.LOOP
Forward loop side receives data (OFF: Reverse loop side receives data)
CPU
Communication with CPU module in execution
125k
ON
Setting status of communication speed (A1SJ71AT23BQ)
250k
500k
1M
CRC
ON (OFF 
if normal)
Code check error of receive data
OVER
The processing of receive data has been delayed.
AB.IF
•"1" has been received consecutively more than stipulated times.
•Receive data length is shorter than stipulated length.
TIME
Data link monitoring time is over.
DATA
The data of error code has been received.
UNDER
Internal processing of send data is not executed constantly.
UND.
F.LOOP
Receive error at forward loop side
R.LOOP
Receive error at reverse loop side
1)
1)
1)
2)
2)
2)
3)
3)
3)
4)
5)
6)
7)