Cable and Gland Installation Notes 
 
 
 
 
  
 
 
 
 
 
 
 
 
 
Step 1
: Make a cable as specified on 
Page 10 or 11. 
Plug in the RJ 45 into the ODU. 
 
 
 
 
 
 
 
 
 
 
 
 
 
Step 2: Support the drop cable and gently 
hand screw the gland body into the ODU 
until the O ring seal is flush to the ODU 
body. 
 
 
Caution
  Do not fit the back shell prior to 
securing the gland body. 
 
 
 
 
 
 
 
 
 
 
 
 
 
Step 3
: Once the gland is fully hand 
screwed into the ODU it may be tight-
ened to a torque of  to 7 ftlbs/10Nm, 
with a 22mm wrench. 
 
 
 
 
 
 
 
 
 
 
 
 
 
Step 4
:When the gland body has been  
fitted, tighten the gland back shell.  
 
 
 
 
Attention  
Do not over tighten the gland 
back shell 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Gland on the right-hand side has been 
over tightened. As a result, the internal 
seal and structure have been damaged. 
 
Should it be necessary to disconnect the 
cable at the ODU (or PTP LPU), this can be 
achieved by removing the gland back shell 
first. Then, wiggle the cable to release the 
tension of the gland body as shown in the 
figure below. Then you can unscrew the 
gland body and depress the RJ45 locking 
tab with a small screwdriver. 
 
12 
Apply small movements to the cable until 
you see a gap here before unscrewing the 
gland body.