Справочник Пользователя для IBM 4986B LanProbe

Скачать
Страница из 143
Local Terminal Configuration
Using a Local Terminal
16 
Using a Local Terminal
You can configure LanProbe by connecting a terminal directly to LanProbe and 
using the LanProbe’s Main Menu. Refer to the following sections for additional 
information on configuring LanProbe after you access the LanProbe’s Main 
Menu: 
z
z
z
z
z
NOTE
The LanProbe is not available to the network when you are in it’s configuration 
menus.
Use the following procedure to access LanProbe’s Main Menu: 
1. Connect a terminal or a personal computer (PC) emulating a terminal to the 
LanProbe’s RS-232 connector using a null modem cable. For more 
information on cables, refer to Appendix A “Cables and Connectors”.
 2. Configure the terminal for 8 bits/character, 1 stop bit, no parity, Xon/Xoff 
handshaking, and a baud rate of 9600.
 3. Connect the Agilent Power Module (0950-2546) to the LanProbe and to a 
power source (either 100-120/VAC or 220-240/VAC). The LanProbe does 
not have a power switch, but is turned on by connecting power.
 4. Start the configuration by quickly pressing the CONFIG button on the back 
of LanProbe one time only. After about 10 seconds, LanProbe displays its 
Main Menu on the terminal. Figure 2-4 on page 17 shows LanProbe’s Main 
Menu. If the Main Menu is not displayed, verify that the previous steps in 
this procedure have been performed correctly.