Local Terminal Configuration
Using a Local Terminal
25
 
Figure 2-10:  Modify/View Serial Port Settings Menu
 2. Select each field requiring configuration (one at a time) by selecting its 
corresponding number as shown in Figure 2-10 and then entering the values 
that are appropriate for your modem’s serial port.
Serial port IP address
Press 
3
 and then enter the serial port IP address for the 
probe. The default Serial Port IP Address is 
0.0.0.0
.
Serial port 
Press 
4
 and then enter the serial port subnet mask for
subnet mask
the probe (optional).  It is recommended that you do not 
change the serial port subnet mask unless there is a 
conflict.  The default Serial Port Subnet Mask is 
255.255.255.192.
Modify/View Interface Values Menu - Firmware Rev 
Interface Type
Serial
1. Port
1.2/Serial
2. Port Type
Not Applicable
3. Serial port IP address
0.0.0.0
4. Serial port subnet mask
255.255.252.192
5. Serial port speed
9600
6. Serial port mode
Direct
7. Serial port hardware flow control
On
8. Modem Init String
^s^M^d1^sATE0Q0V1X4 S0=1...
9. Modem Hangup String
^d2^s+++^d2^sATH0^M^d2
10. Modem Connect Responses
/CONNECT/300/CONNECT/1200/...
11. Modem No-Connect Responses
/NO CARRIER/BUSY/NO DIALT... 
S. Save Changes and Exit
0. Cancel Changes and Exit