Справочник Пользователя для Printronix Integrated Network Interface Card

Скачать
Страница из 310
Cannot PING The Printer
185
AS/400 Troubleshooting
Use this section to resolve problems configuring AS/400 on TCP/IP 
networks.
Cannot PING The Printer
If you have problems trying to ping the printer:
Verify the configuration of AS/400, including the printer and any 
intervening devices such as routers and bridges.
Verify that the AS/400 line description is varied on and the 
printer is turned on and displays a status of ONLINE.
Verify that the AS/400 TCP/IP interface is active.
PSF/400 Terminates When Initialized
If PSF/400 terminates when you initialize it for IPDS printing and 
issues message PQT3603, check for the following error codes:
Code 10 means an incorrect RMTSYS or RMTLOCNAME (V3R2, 
V3R7, or V4R1) has been specified for the printer.
Code 15 means that PSF/400 timed out waiting for the printer’s 
response. Check the value you entered for Activation Timer 
when using WRKAFP2, CRTPSFCFG (V3R2), or CRTDEVPRT 
(V3R7 or V4R1).
Codes 20-39 indicate a general communications failure. Make 
sure all of the components in your network are operational, 
such as routers. If necessary, call Printronix technical support.
Codes 40-59 indicate a logic error between PSF and the printer 
control unit. Contact Printronix technical support.