Справочник Пользователя для Nortel Networks AN/DC

Скачать
Страница из 150
Requirements for European Operation
312410-A Rev 00
D-3
 
Synchronous Cabling Requirements
Refer to 
 through 
 and 
 through 
 for 
synchronous interface cabling information.
Note the following compliance requirements:
V.28 compliance requires the use of an Order No. 7837 cable
V.35 compliance requires the use of an Order No. 7220 cable
X.21 compliance requires the use of an Order No. 7224 cable 
Figure D-1.
Cable 7837 (V.28 Compliant)
Table D-6.
WAN Interface (Order No. 7837)
Nortel Networks Termination
Remote Termination
Pin
Signal
Pin
Signal
  1
Frame Ground
  1
Frame Ground
  2
Send Data+
  2
Send Data 
  3
Receive Data+
  3
Receive Data
  4
Request to Send+
  4
Request to Send
  5
Clear to Send+
  5
Clear to Send
  6
Data Set Ready+
  6
Data Set Ready
  8
Data Terminal Ready+
20
Data Terminal Ready
(continued)
Pin 1
Pin 16
Pin 31
Pin 15
Pin 30
Pin 44
15 Feet
Pin 13
Pin 1
Pin 25 
Pin 14
44-position D-Sub plug with screw locks
(ground shield connected to backshell)
25-position D-Sub plug receptacle with screw locks
(ground shield connected to backshell)
AN0081A