5.2 Known 
problems 
When using the debug interface through the level-converter on the SmartRf04EB. (Shown in 
Figure 1 and Figure 2) it might become unstable. This problem is more likely to occur a low 
voltages or with crosstalk in the cable at high interface speed. 
 
First make sure that the 10 pin flat cable used to connect the CC2511 USB Dongle to the 
SmartRF04EB is as short as possible. 
Next it might be necessary to reduce the debug interface speed in order to achieve stable 
operation.  
In the IAR workbench do the following: 
•  Highlight the project name by clicking on it in the “Files” window. (See Figure 6) 
•  Go to Project -> Options… 
•  Select the Category “Chipcon” 
•  Click on the “Target” tab. 
•  Check the “Reduce interface speed” option. (See Figure 7) 
 
 
 
Highlight the 
project name 
Figure 6: Highlight the project name 
 
 
 
Check the 
“Reduce interface 
speed” option. 
Figure 7: Reduce interface speed 
 
 