ACTIVATING RMON GROUPS
The initial configuration of the EMM-E6 at installation does not provide 
the activation of the RMON Default and Host Groups. These management 
groups may be activated or deactivated through local management using 
OID Sets. As the specific OID used to control each RMON bundle is 
dependent upon the presence or absence of BRIMs and their type, an 
SNMP Get is necessary to determine the OID instances of the RMON 
bundles before they may be enabled or disabled.
chCompName
Description: Returns OID values for the location of the RMON 
bundle OIDs in the device being examined. These values may be 
used in conjunction with the chCompAdminStatus OID (below) 
to activate and deactivate the individual RMON bundles.
Object Identifier:
1.3.6.1.4.1.52.4.1.1.2.4.1.5
Data Type:
Integer
Access Policy:
read-write
chCompAdminStatus
Description: Enables and disables the RMON Default Group for 
an EMM-E6.
Object Identifier:
[Result of above SNMP Get]
Data Type:
Integer
Values:
7
disable
3
enable
Access Policy:
read-write