Справочник Пользователя для Intel ECB-865

Скачать
Страница из 112
ECB-865 
ECB-865 User’s Manual  13  
 
3.5  M-Systems’ DiskOnChip Flash Disk 
ECB-865 reserves a 32-pin DIP socket to support M-Systems’ DiskOnChip flash disk up to 
288 MB. The DiskOnChip is based on pure ISA bus and without PnP (Plug and Play) 
function. Before the installation, make sure that the DiskOnChip I/O address jumper is set 
properly to prevent the I/O resource conflict. 
3.5.1 Installing 
DOC 
Align the DOC with the pinholes on the socket. Make sure that the notched corner or dot 
mark (pin 1) of DOC corresponds to notched corner of the socket. Then press the DOC 
gently until it fits into place. If installation procedure is correct, the flash disk can be viewed 
as a normal hard disk to access read/write data now. 
Note: 
Please make sure that your DOC is properly inserted. Place the DOC in wrong 
direction will damage the flash device. 
If you system would like to boot from the flash disk, it is recommended to refer to the 
application note provided by M-Systems first. You can easily obtain the application note 
from M-Systems’ DiskOnChip user’s manual or from their web site as below. 
3.6 Expansion 
Interface 
The ECB-865 reserves an 80-pin proprietary PCI interface, J22, for PCI device such as 
LAN, Audio, SCSI, Video Capture expansion in the future. This installation of expansion 
module is very simple and easy. Without any special tool, all you need to do is just make 
the board-to-board connection and lock up the screw. For more information about the 
expansion module, please refer to the instruction manual attached with each module. 
3.7  Installing the Single Board Computer 
To install your ECB-865 into chassis or proprietary environment, the following steps have 
to be followed. 
 
Make sure all jumpers are properly set. 
 
Install and configure CPU and memory module correctly. 
 
Place the ECB-865 into the dedicated position in your system. 
 
Attach cables to peripherals. 
Note: 
Please ensure that your SBC is properly installed and fixed by mechanism. 
Otherwise, the system might be unstable or do not work due to bad contact of 
golden finger and slot.