Справочник Пользователя для Vermont Casting 2477
15
Dutchwest Non-Catalytic Convection Heater
30002314
Distance from Center of Flue Collar to Wall in Top-Exit Installations
Dutchwest Convection Heater Model 2477
NOTE: These are not clearance distances. These measurements indicate where the centerline of the flue col-
lar will be for various installations. Measurements are from the centerline of the flue collar to the wall, not the
wall protector.
NOTE: These are not clearance distances. These measurements indicate where the centerline of the flue col-
lar will be for various installations. Measurements are from the centerline of the flue collar to the wall, not the
wall protector.
ST427
dutchwest
flue centerline
6/30/00 djt
A
B
C
E
D
F
C
F
Chimney Connector
Side
Rear
Corner
Side
Rear
Corner
Listed, Approved
(A) 35”
(B) 13”
(C) 19⁵⁄₈”
(D) 21”
(E) 13”
(F) 19⁵⁄₈”
Double-wall, with
(889 mm)
(330 mm)
(499 mm)
(533 mm)
(330 mm)
(499 mm)
flue collar shield
Single wall, with
Single wall, with
(A) 28”
(B) 12”
(C) 18⁵⁄₈”
(D) 19”
(E) 9”
(F) 16¹⁄₈”
Connector heat shields
(711 mm)
(305 mm)
(473 mm)
(483 mm)
(229 mm)
(410 mm)
and flue collar shield
Single wall with no
Single wall with no
(A) 35”
(B) 22”
(C) 26⁵⁄₈”
(D) 19”
(E) 17”
(F) 22⁵⁄₈”
heat shields
(889 mm)
(559 mm)
(676 mm)
(483 mm)
(432 mm)
(575 mm)
UNPROTECTED SURFACES
PROTECTED SURFACES
Corner
Corner
Parallel Installations
Installations Parallel Installations
Installations
ST427