Справочник Пользователя для Regency L676-NG1

Скачать
Страница из 48
Regency
®
 L676-1 Direct Vent Gas Fireplace
13
INST
ALLA
TION
Vent restriction is required for certain venting 
installations, see the diagrams in the "Venting
Arrangements" section to determine if they are 
required for your installation.
The Vent Restrictor plate is located on the inside 
top of the fi rebox.
INSTALLATION
VENT RESTRICTOR POSITION
Screws for plugging the holes.
(all holes must be plugged with a screw).
Screw holes for fi xing the restrictor plate.
Vent Restrictor Plate
To set the vent restriction as indicated in the 
venting arrangements diagrams, refer to the 
following instructions;
3)  Remove the glass door.
 
a.  Release the 2 door latches on the left      
     and right side at the top of the fi rebox.
 b.  Swing the door out from the top and release   
the hinge on the left side of the  door and 
lift out.
Latch
Latch Location
6)     Once the vent restrictor plate is in the required 
position, secure with screws.
Door
Hinge
1)  Remove the right side mesh by gathering the 
mesh together and lifting the curved end of 
the rod up and out of the bracket located on 
the top right of the glass frame.
 
Now slide the straight end of the rod out from 
the bracket located on the middle inside top 
of the outer shell. Repeat for left side.
Front Cover Plate
Right Side Pin Shown
2)  Remove the front cover plate by lifting up 
off of the pins on the left and right side of 
the fi rebox.
Right Side Rod with Screen Removed
Vent Restrictor Set 4
Baffl e plate
Note:  Used only with specifi c limited 
     horizontal termination.  See chart on 
     p. 19 in this manual for details.
    
Position the baffl e plate on the top inside 
wall of the fi rebox, push it back until it  
    contacts the back wall of the fi rebox. 
    Center it between the 2 relief doors (see 
above diagram), secure with 2 self tapping 
screws provided.
7) Vent Restrictor Set 4 = combination of 
    Vent Restrictor Set 1 + installation of  the    
baffl e plate (see below).
Relief Doors
4)  Remove the screws that hold the vent 
restrictor plate in place.
5)   Adjust the vent restrictor plate to the required 
vent restrictor position as per the diagrams 
shown.