Operating Instructions
7
TROUBLESHOOTING
If leds • and •••• are flashing: 
This is the Service Indicator. It signifies time to service (replace 
or clean) the filter(s).
Pressing any button will turn off the Service Indicator leds. 
When the unit is switched on again the Service Indicator will 
resume flashing. After changing the filter(s), the Service 
Indicator should be reset in Program Setting 2. Contact your 
service person.  
If led 
AUTO
 is flashing: 
Air Quality Analyzer is warming up. After 5 minutes the Air 
Quality Analyzer is ready and air cleaner will start running in 
AUTO
 mode.
If led 
STANDBY
 is flashing: 
High Voltage Output problem in the collecting cell(s).
If there is a dead short in the cell for over 60 seconds the 
STANDBY
 led flashes. Power will be interrupted to the cell(s) for 
10 minutes which may allow the cause of the problem (e.g. 
hair) to flow out of the collecting cell. After 10 minutes the high 
voltage will return to the cell. If there is still a short in the cell 
the high voltage will again be interrupted for 10 minutes, etc. 
This loop stops at the fourth time a dead short condition is 
detected. Upon detection, the software blocks the fan control 
and the unit quits operating. The collecting cell should be 
cleaned to see if it can be returned to service or requires further 
repair. Contact your service person.  
Note: After one crackle or snap (arcing) the high voltage will 
drop to 7000 Volts and slowly build up to the programmed 
output. If there are more than 20 crackles or snaps during one 
minute, the software blocks the high voltage for 45 seconds, 
after which the voltage slowly rebuilds.