Справочник Пользователя для Ducane (HVAC) Horizontal 80

Скачать
Страница из 4
FPBB050A3B
FPBB075A3B
FPBB100A4B
FPBB125A5B
GAS
NATURAL (LP with conversion kit) 
INPUT RATE (BTU per Hour)
50,000
75,000
100,000
125,000
HEATING CAPACITY (BTU per Hour)
40,000
61,000
81,000
101,000
AFUE (ISOLATED COMB. SYSTEM)
80%
TEMPERATURE RISE
30 - 60 F
40 - 70 F
VOLTS / PHASE / HERTZ
115 /1/ 60
STATIC PRESSURE (CERTIFIED MAX)
0.50" W.C.
BLOWER MOTOR HORSEPOWER
1/3
1/2
3/4 
BLOWER WHEEL (DIA. X WIDTH)
10 x 6
12 x 9
12 x 12
NUMBER OF HEAT EXCHANGERS
2
3
4
5
LIMIT CONTROL, SNAP DISK STYLE
150 F
170 F 
170 F
150 F
IGNITION CONTROL
DIRECT SPARK
TRANSFORMER
40 VA, 115VAC PRIMARY, 24VAC SECONDARY, FOOT-MOUNTED
INTEGRATED CONTROL SYSTEM
INTEGRATED FURNACE CONTROL
SHIPPING DIMENSIONS
54 X 26 X 25 3/4
54 X 29 X 25 3/4
54 X 33 X 25 3/4
SHIPPING WEIGHT
144
153
175
197
MAXIMUM DESIGN OUTLET TEMP.
170 F
AUXILIARY LIMIT
130 F 
140 F
UNIT SPECIFICATIONS 
HORIZONTAL 80
TM
D u c a n e   G a s   F u r n a c e
FPBB075A4B
FPBB100A5B
GAS
NATURAL
INPUT RATE (BTU per Hour)
75,000
100,000
HEATING CAPACITY (BTU per Hour)
61,000
81,000
AFUE (ISOLATED COMB. SYSTEM)
80%
TEMPERATURE RISE
30 - 60 F
VOLTS/PHASE/HERTZ
115/1/60
STATIC PRESSURE (CERTIFIED MAX)
0.50 "W.C. 
BLOWER MOTOR HORSEPOWER
1/2 
3/4
BLOWER WHEEL (DIA. X WIDTH)
10 X 6
12 X 9
NUMBER OF HEAT EXCHANGERS
3
4
LIMIT CONTROL, SNAP DISK STYLE
170 F 
160 F 
IGNITION CONTROL
DIRECT SPARK
TRANSFORMER           
40 VA. 115VAC PRIMARY, 24VAC SECONDARY, FOOT-MOUNTED
INTEGRATED CONTROL SYSTEM
INTEGRATED FURNACE CONTROL
SHIPPING DIMENSIONS
54 1/2 X 26 X 25 3/4
54 1/2 X 29 X 25 3/4
SHIPPING WEIGHT
157
183
MAXIMUM DESIGN OUTLET TEMP.
170 F
AUXILIARY LIMIT
130 F
140 F
UNIT SPECIFICATIONS HIGH AIR FLOW MODELS