Dutchwest Natural Vent Gas Heater
30002008
Burner Information
The appliance must only use the gas specified on the 
rating plate, unless converted using a CFM Corporation 
Fuel Conversion Kit. Refer to Page 23 for the correct 
Fuel Conversion Kit for your model.
Conversion instructions are provided with each kit and 
beginning on Page 16 in this manual.
THIS APPLIANCE SHOULD BE CONNECTED 
TO THE GAS SUPPLY ONLY BY A QUALI-
FIED GAS SERVICE TECHNICIAN. FOLLOW 
ALL LOCAL CODES.
THERE MUST BE A GAS SHUT-OFF BE-
TWEEN THE STOVE AND THE SUPPLY.
In order to connect Natural Gas, use a fitting with 
3/8” NPT nipple on the valve side and 1/2” natural gas 
supply line with an input of 28,000 BTUs at a manifold 
pressure of 3.5” and a minimum inlet supply pressure of 
5.5” w.c.
In order to connect Propane, use a fitting with 3/8” 
NPT nipple on the valve side and 1/2” propane gas 
supply line with an input of 26,000 BTUs at a manifold 
pressure of 10.0” and a minimum inlet supply pressure 
of 11.0” w.c. 
Install ON/OFF Switch
The switch assembly parts are found in the parts bag.
1.  Attach switch assembly to left rear side of stove 
shroud (when facing shroud) using two screws and 
existing holes in shroud. (Fig. 19)
2.  Run wires down back of stove, under bottom of rear 
shroud to valve.
3.  Attach wires to valve terminals. (Fig. 20)
ST315
attach switch assy
1/31/00   djt
Switch As-
sembly
Screws
Existing 
Holes
ST315
Fig. 19   Attach switch assembly to rear shroud.
PILO
T
ADJ
TP
TH
TPTH
ST228
attach switch
wires to valve
12/99
ST228
Fig. 20  Attach switch wires to valve.
Install the Log Set
1.  Remove the logs from their packaging, and inspect 
each piece for damage. DO NOT INSTALL DAM-
AGED LOGS.
2.  Install the rear log centering it side to side on the 
sheet metal shelf at the back of the firebox. (Fig. 21) 
The log will touch both sides and the back wall of the 
firebox.
3.  Install the right log by engaging hole on bottom with 
pin on the rear log. (Fig. 21) Then set right bottom 
side on the burner so the edge of the log touches 
the right side of the firebox. The right log does not 
use the locator pins on the burner to stay in place.
4.  Install the left log by engaging hole on bottom with 
pin on rear log. (Fig. 21) Then set left bottom side 
on the burner so the edge of the log touches the left 
side of the firebox.
5.  Loosely sprinkle the lava rocks directly on top of the 
burner in front of and between the decorative grate 
and the right and left logs. Use the lava rock to cover 
brackets on the burner. (Fig. 22)
 
Thermostat  
 
 
Wire / Gauge 
Maximum Run
 
18 
40 feet
 
20 
25 feet
 
22 
16 feet
Thermostat Connection (optional)
Use only a thermostat rated for 500 - 750 millivolts.
Check the table below for the appropriate gauge ther-
mostat wire to use for the length of lead required in your 
installation.
1.  Install the wall thermostat in the desired location and 
run the wires to the stove location. Terminate these 
leads with 1/4” female connectors.
2.  Connect the thermostat wires to the valve.  (Fig. 20)