Справочник Пользователя для Desa FMH26TP
3
107106
OWNER’S MANUAL
PRODUCT IDENTIFICATION
LOCAL CODES
Install and use fireplace with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel Gas
Code ANSI Z223.1/NFPA 54*.
local codes. In the absence of local codes, use
the latest edition of The National Fuel Gas
Code ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Figure 1 - Vent-Free Propane/LP Gas Compact Fireplace
PRODUCT
FEATURES
FEATURES
SAFETY PILOT
This fireplace has a pilot with an Oxygen
Depletion Sensing (ODS) safety shutoff sys-
tem. The ODS/pilot is a required feature for
vent-free room fireplaces. The ODS/pilot shuts
off the fireplace if there is not enough fresh air.
Depletion Sensing (ODS) safety shutoff sys-
tem. The ODS/pilot is a required feature for
vent-free room fireplaces. The ODS/pilot shuts
off the fireplace if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This fireplace has a piezo ignitor. This sys-
tem requires no matches, batteries, or other
sources to light fireplace.
tem requires no matches, batteries, or other
sources to light fireplace.
THERMOSTATIC HEAT
CONTROL
CONTROL
This fireplace has a thermostat sensing bulb
and a control valve. The thermostat will
automatically modulate the heat output to
maintain a consistent room temperature.
This results in greater fireplace comfort.
This can also result in lower gas bills.
and a control valve. The thermostat will
automatically modulate the heat output to
maintain a consistent room temperature.
This results in greater fireplace comfort.
This can also result in lower gas bills.
Ignitor Button
Screen
Fireplace
Cabinet
Cabinet
Logs
Control Knob
UNPACKING
1.
Remove log box and fireplace from
carton. The hood is not attached.
carton. The hood is not attached.
IMPORTANT:
The fireplace hood is
inside the cardboard protective end
wrap on the left side of fireplace (as
viewed from front). A decal is on the
outside of the cardboard end wrap stat-
ing hood is enclosed (see Figure 2).
wrap on the left side of fireplace (as
viewed from front). A decal is on the
outside of the cardboard end wrap stat-
ing hood is enclosed (see Figure 2).
2.
Remove hood from cardboard protec-
tive end wrap as shown in Figure 2.
tive end wrap as shown in Figure 2.
3.
Remove all protective packaging ap-
plied to fireplace for shipment.
plied to fireplace for shipment.
4.
Make sure your fireplace includes one
hardware packet.
hardware packet.
5.
Check fireplace for any shipping
damage. If fireplace is damaged,
promptly inform dealer where you
bought fireplace.
damage. If fireplace is damaged,
promptly inform dealer where you
bought fireplace.
SAFETY
INFORMATION
INFORMATION
Continued
15. Operating fireplace above elevations of
4,500 feet could cause pilot outage.
16. Do not operate fireplace if any log is
broken. Do not operate fireplace if a
log is chipped (dime-sized or larger).
log is chipped (dime-sized or larger).
17. To prevent performance problems, do
not use propane/LP fuel tank of less
than 100 lbs. capacity.
than 100 lbs. capacity.
18. Provide adequate clearances around air
openings.
IMPORTANT:
THIS PACKAGE CONTAINS A
FIREPLACE HOOD. UNWRAP
CARTON AND REMOVE HOOD
BEFORE DISCARDING
PROTECTIVE PACKAGING.
1
2
Figure 2 - Removing Fireplace Hood
Hood
Cardboard
Protective
Fireplace
End Wrap
Protective
Fireplace
End Wrap
Hood
Enclosed
Decal
Enclosed
Decal