Справочник Пользователя для Mitsubishi Electronics -LD62D

Скачать
Страница из 136
119
APPENDICES
A
Appendix
 4 
Dif
ferences
 B
e
tw
een 
L S
eries 
and 
Q
 Ser
ies
 M
odules
 
Appendix 4
Differences Between L Series and Q Series 
Modules
The following table describes the differences between the L series modules and the Q series modules in 
specifications.
*1
Coincidence output derating (on ratio) has been set to the high-speed counter module. (
*2
The high-speed counter module does not have a built-in fuse for blown fuse detection. Install a fuse for each external 
terminal to prevent the external devices or module from being burnt out or damaged if a load shorts. (
Item
LD62
LD62D
QD62
QD62D
Coincidence output derating (on ratio)
Limited
No limitations
Coincidence output external auxiliary 
power supply and current consumption
43mA (TYP., 24VDC and all points on/common) 8mA (TYP., 24VDC/point)
Blown fuse detection
Not supported
No FUSE LED is equipped.
XF: Use prohibited
Supported
The FUSE LED is equipped.
XF: Blown fuse detection flag