Instruction Manual
 
IM-106-4050 Original Issue
March 2006
OxyBalance Oxygen Display
and Averaging System
http://www.processanalytic.com
Section 2
Installation
OVERVIEW
This section describes:
1. Wall-mounting of the OxyBalance system.
2. The necessary wiring schematics for proper connection of the 
OxyBalance system.
3. Setup procedures conducted through the PanelView Plus 600 on how to 
configure, assign nomenclature, change/update display settings, and 
assigning the O
2
 probes to the average outputs.
SYSTEM 
CONSIDERATIONS
Prior to installation of the OxyBalance system, check for all components 
necessary to install the system completely. When selecting a mounting 
location, determine where the OxyBalance system will be placed in terms of 
serviceability, ambient temperatures, environmental considerations, and 
convenience. 
Before starting to install this equipment, read the "Safety Instructions" in Appendix A: Safety 
Data. F
ailure to follow the safety instructions could result in serious injury or death.
Disconnect all power before installing or replacing components. Failure to disconnect power 
may result in electrical shock and/or damage to the terminal.
Install all protective equipment covers and safety ground leads after installation. Failure to 
secure covers and ground leads could result in serious injury or death.