Справочник Пользователя для Newcon Optik DN310

Скачать
Страница из 10
 
 
INSTALLATION RULES. 
 
a. Variant I – Adapter rail with Standard Prism type. 
 
Device is fixed with the help of the following parts: 
 
         
 
 
 
Front and rear feet (2, 3) are the standard feet with Standard prism 
(4), manufactured by the companies that produce mounts (for 
example, Ernst Apel GmbH Germany)). The mount of Standard 
prism type (4) and screws (5) are optional. 
Installation of the device should be performed according to the 
following rules: 
 
• Check the prominence of fixation screws (5) that bind the prism 
(4) to the body (1) of the device over the top surface of the prism.  
The prominence must not be less than 2.5 mm or more than 3.0 
mm.  This is especially important if in the body of the device 
there is a dead threaded hole.  For the reach-through holes the 
prominence may reach 3.5 mm, but must not be less than 2.5 
mm.  In order to meet this requirement you can cut the threaded 
part of the screws at length; 
 
 
10 
• Install the feet onto the rail (4).  Insert the feet (2, 3) in the rifle.  Sliding 
the rail in the feet, find the position, in which your eye will meet the 
edge of the eyeshade of the device or will be 2-5 cm apart for big 
calibres (like .375 H&H Mag). The position of the device must be 
comfortable enough so that you would not have to reach forward for 
convenient observation; 
• Cut the excessive part of the rail (4); 
• Keeping the chosen position of the device, fix the feet (2, 3) to the rail 
(4) according on the instruction of the feet producer; 
• Prepare the glue according to an instruction (the glue need to be of a 
certain strength not less than 200 kg/cm
2
, for example epoxy) and apply 
it to (A) surface of the rail.  The surface of the screws must remain free 
of the glue.  This is especially important for possibility to repair the 
device or to remove the binding rail for installation on a different rifles; 
• Apply hermetic (silicone type) to the threading of the screws (5). 
• Fix the bar to the body of the device with the help of the screws (5), cut 
to meet the needed length; 
• Remove excessive glue (that is pushed out in the points the rail is 
connected to the body of the device) with the help of dry cloth and 
alcohol-moistened cotton wool, and let the glue take according to its 
instruction (for example, 24 hours for epoxy). 
Installation is completed and the device is ready for use as a hunting scope. 
 
b. Variant II – Adapter rail with 7/8’’ Weaver prism type. 
 
Fastening of the device is made with the help of the following 
parts: 
 
11 
1- Device 
body 
2-  Front cradle for Standard prism 
3-  Rear feet for Standard prism 
4-  Mount of the Standard prism type 
5- Fixing 
screws