Справочник Пользователя для Mitsubishi Electronics AJ61QBT11

Скачать
Страница из 294
A - 8 
3.5  Buffer Memory......................................................................................................................................... 3-19 
3.5.1  Buffer memory list ............................................................................................................................ 3-19 
3.5.2  Buffer memory details ...................................................................................................................... 3-21 
4.  FUNCTIONS....................................................................................................................................4-  1 to 4-30 
4.1  Function List ............................................................................................................................................ 4-  1 
4.2  Communication Between the Master Station and Remote I/O Station................................................. 4-  3 
4.3  Communication Between the Master Station and Remote Device Station........................................... 4-  5 
4.4  Communication Between the Master Station and Local Station ........................................................... 4-10 
4.5  Communication in Compound Systems................................................................................................. 4-16 
4.6  Reserved Station Function ..................................................................................................................... 4-22 
4.7  Error Invalid Station Function ................................................................................................................. 4-23 
4.8  Data Link Status Setting When the Master Station Programmable Controller CPU Has an Error ...... 4-24 
4.9  Setting the Status of Input Data from a Data Link Faulty Station.......................................................... 4-25 
4.10  Module Reset Function from a Sequence Program ............................................................................ 4-26 
4.11  Data Link Stop/Restart.......................................................................................................................... 4-27 
4.12  RAS Function ........................................................................................................................................ 4-28 
4.12.1  Automatic return function ............................................................................................................... 4-28 
4.12.2  Slave station cut-off function.......................................................................................................... 4-29 
4.12.3  Station number overlap checking function .................................................................................... 4-30 
5.  DATA LINK PROCESSING TIME ..................................................................................................5-  1 to 5-24 
5.1  Status of Each Station When an Error Has Occurred ........................................................................... 5-  1 
5.2  Link Scan Time ....................................................................................................................................... 5-  4 
5.3  Transmission Delay Time ....................................................................................................................... 5-  5 
5.3.1  Master station   remote I/O station................................................................................................ 5-  5 
5.3.2  Master station   remote device station .......................................................................................... 5-  7 
5.3.3  Master station   local station.......................................................................................................... 5-11 
5.3.4  Master station   intelligent device station ...................................................................................... 5-15 
5.4  Dedicated Instruction Processing Time.................................................................................................. 5-16 
5.4.1  Master station 
 local station ......................................................................................................... 5-16 
5.4.2  Local station 
 local station............................................................................................................ 5-20 
5.4.3  Master station 
 intelligent device station ..................................................................................... 5-22 
6.  PARAMETER SETTING.................................................................................................................6-  1 to 6-10 
6.1  Procedure from Parameter Setting to Data Link Startup....................................................................... 6-  1 
6.1.1  Relationship between buffer memory, E
2
PROM and internal memory.......................................... 6-  1 
6.1.2  Procedure from parameter setting to data link start........................................................................ 6-  3 
6.2  Parameter Settings ................................................................................................................................. 6-  4 
6.3  Setting from a Sequence Program ......................................................................................................... 6-  5 
7.  DATA LINK PROCEDURE .............................................................................................................7-  1 to 7-24 
7.1  Data Link Procedure ............................................................................................................................... 7-  1 
7.2  Installation and Setting............................................................................................................................ 7-  2 
7.2.1  Precautions when handling the module .......................................................................................... 7-  2 
7.2.2  Setting environment ......................................................................................................................... 7-  3