8.3  Remote Password
This section provides the list of parameters for use of remote password and describes parameter details.
A remote password is set for an Ethernet module, serial communication module, modem interface module, 
or Built-in Ethernet port QCPU
.
Figure 8.19 Remote password settings dialog box
Table8.21 Remote password setting list
Item
Parameter No.
Description
Setting range
Default
Reference
Password settings
-
Enter a remote password.
Four characters or less 
(alphanumeric characters, special 
symbols)
-
• QnUDE(H)CPU:
QnUCPU User's 
Manual 
(Communication 
via Built-in 
Ethernet Port)
• QJ71E71:
Ethernet module 
manual
• QJ71C24:
Serial 
communication 
module manual
• QJ71CMO:
Modem interface 
module manual
Password 
active 
module 
settings
Model 
name
-
Select a model name of the module 
for which the remote password set  
to the CPU module is checked.
• QnUDE(H)CPU
• QJ71E71
• QJ71C24/CMO
-
Start XY
-
Set the start address of the module 
for which the remote password is 
checked.
0000
H
 to 0FE0
H
-
Detail
-
Set details of the remote password 
for the QJ71E71.
-
-
User connection No.
-
Select user connection No.
Connection 1 to Connection 16
-
System connection
-
Select a valid port of the remote 
password for system connection.
Specify a valid port of the remote 
password.
• Auto open UDP port
• FTP transmission port (TCP/IP)
• GX Developer transmission port 
(TCP/IP)
• GX Developer transmission port 
(UDP/IP), Dedicated instruction, 
CC IE Control, MNET/10(H) relay 
transmission port.
• HTTP  port
-