Справочник Пользователя для Mitsubishi Electronics QnUCPU

Скачать
Страница из 630
CHAPTER9 DEVICES
9
2
3
4
5
6
7
8
9.
 I
ndex 
Regist
er 
(Z
)/S
tandard
 Dev
ic
e
 Res
is
ter
 (Z
)
9.
6.
 Sw
itching f
rom
 the scan exec
ut
ion t
ype progr
am t
o
 t
he int
e
rr
upt
/fixed sc
an 
ex
ecut
ion t
ype 
program
9
 
-
 
49
9.6.3  Switching from the scan execution type program to the interrupt/fixed scan 
execution type program
The CPU module performs the following when switching from the scan execution type program to the interrupt/
fixed scan execution type program.
 
 • Saving and restoring the index register data
 • Saving and restoring block numbers of the file register
(1) Setting for saving and restoration
Saving and restoration setting can be enabled in the PLC system tab of the PLC parameter dialog box. 
To disable writing to the index register in the interrupt/fixed scan execution type program, select "High speed 
execution" in the Interrupt program/Fixed scan program setting area.
If this setting is enabled, the program will switch faster than before.
Figure 9.62 Interrupt/fixed scan program setting