5.4 Network Dedicated Instruction
5.4.15 REQ instruction
5-183
J_REQ, G_REQ
5
MODULE DEDICA
TED 
INSTRU
CTI
O
N
J_
RE
Q,
 G
_
R
E
Q
5.4.15  
REQ instruction
J_REQ, G_REQ
*1: Local devices and file registers per program cannot be used as setting data.
Function
Remotely runs or stops a programmable controller on another station.
Also, reads/writes clock data from/to a programmable controller on another station.
J(P)_REQ
G(P)_REQ
P: Executing condition
:
 indicates any of the following 
instructions.
J_REQ
JP_REQ
G_REQ
GP_REQ
Input argument
EN:
Executing condition
:Bit
Jn*:
Network number of the host station (1 to 239, 254)
254: Network specified in 
"
Valid module during other station 
access
"
:ANY16
Un*:
Start I/O number of the module
(00 to FE: Higher two digits when expressing the I/O number in 
three digits)
:ANY16
s1:
Variable that stores control data
:Array of ANY16 [0..17]
s2:
Variable that stores request data
:Array of ANY16 [0..5]
Output argument
ENO:
Execution result
:Bit
d1:
Variable that stores response data
:Array of ANY16 [0..5] 
d2:
Variable that turns ON upon completion of the instruction
d2[1] also turns ON at the time of error completion.
:Array of bit [0..1]
Setting
data 
*1
Internal device
R, ZR
J
\
U
\G
Zn
Constant Others
Bit
Word
Bit
Word
CC IE F
CC IE C
NET/H
Ether
Structured ladder/FBD
EN
ENO
Jn*
d1
d2
s1
s2
J_REQ
EN
ENO
Un*
d1
d2
s1
s2
G_REQ
ST
J_REQ
(EN, Jn*, s1, s2, d1, d2);
ENO:=
G_REQ
(EN, Un*, s1, s2, d1, d2);
ENO:=
s1
s2
d1
d2