2-12
2.5 Built-in I/O Function Instruction
2.5.1 Positioning function dedicated instruction
2.5  
Built-in I/O Function Instruction
2.5.1  
Positioning function dedicated instruction
Classification
Instruction name
Argument
Processing details
Executing 
condition
Page
Positioning start
IPPSTRT1
n
Specifies a data number to be executed from 
"Positioning Data" No. 1 to No. 10 which are 
previously set in GX Works2, and starts the 
positioning.
IPPSTRT1P
n
IPPSTRT2
n
IPPSTRT2P
n
IPDSTRT1
Regardless of "Positioning Data" No. 1 to No. 10 
which are previously set in GX Works2, starts 
the positioning using the data stored in the 
devices starting from the one specified for 
control data.
IPDSTRT1P
IPDSTRT2
IPDSTRT2P
IPSIMUL
n1, n2
Starts the positioning of the axis 1 "Positioning 
Data" number and the axis 2 "Positioning Data" 
number simultaneously.
IPSIMULP
n1, n2
OPR start
IPOPR1
Specifies a method and starts the OPR of the 
specified axis.
IPOPR1P
IPOPR2
IPOPR2P
JOG start
IPJOG1
Starts the JOG operation of the specified axis.
IPJOG2
Absolute position 
restoration
IPABRST1
Executes the absolute position restoration of the 
specified axis.
IPABRST2
Stop
IPSTOP1
-
Stops the axis in operation.
IPSTOP2
-
Speed change
IPSPCHG1
Changes the speed of the specified axis.
IPSPCHG1P
IPSPCHG2
IPSPCHG2P
Target position 
change
IPTPCHG1
Changes the target position of the specified 
axis.
IPTPCHG1P
IPTPCHG2
IPTPCHG2P
s
s
s
s
s
s
s
s
s1
s2
s1
s2
s
d
s
d
s
s
s
s
s
s
s
s