8   PROGRAMMING 
MELSEC-QnA 
 
The timing when the link special register (SW) data is updated differs depending on the 
number. 
The update timing is indicated in Table 8.3. 
 
Table 8.3 Update timing of the link special register 
 
Link special register 
Data update timing 
Link special register 
Data update timing 
SW0041 SW0071 
Updated independently regardless of SB 
(Update after each station is stabilized.) 
SW0045 
Updated independently regardless of SB 
SW0072 
When SB0074 changes 
SW0060 
When SB0060 changes 
SW0074 to SW0077 
When SB0075 changes 
SW0061 
When SB0061 changes 
SW0078 to SW007B 
When SB0080 changes 
SW0062 
SW0080 to SW0083 
Updated independently regardless of SB
SW0067 
SW0088 to SW008B 
When SB0090 changes 
SW0068 SW0090 
SW0069 
SW0098 to SW009B 
SW006A 
SW009C to SW009F 
SW006D 
SW00B4 to SW00B7 
SW006E SW00B8 
SW006F SW00B9 
Updated independently regardless of SB
SW0070 
Updated independently regardless of SB 
– –