Справочник Пользователя для Mitsubishi Electronics A1SJ61QBT11

Скачать
Страница из 294
 
 
 
4 - 18 
4   FUNCTIONS 
MELSEC-QnA 
 
[Data link startup] 
1
 Turn on the refresh instruction (Yn0) and make the remote output (RY) data valid. 
When the refresh instruction (Yn0) is off, all the remote output (RY) data is treated 
as 0 (off). 
 
2
 Turn on the data link startup by the E
2
PROM parameters (Yn8) and start the data 
link. 
However, the parameters must be set in the E
2
PROM beforehand. 
When the data link is started normally, the host data link status (Xn1) turns on. 
 
POINT 
 
The data link can also be started from the parameters written in the "parameter data area" in 
the buffer memory. (Refer to chapter 6.) 
 
[On/off data from remote I/O station/remote device station/local station   the master 
station] 
3
 The input of remote I/O station, remote input (RX) of the remote device station and 
the remote output (RY) of the local station are automatically (for each link scan) 
stored in the master station's "remote input (RX)" in the buffer memory and local 
station's "remote output (RY)" in the buffer memory. 
 
4
 The data in local station's "remote output (RY)" is also stored in other local station's 
"remote output (RY)". 
 
5
 The input status stored in the "remote input (RY)" in the buffer memory is written to 
the programmable controller CPU with the FROM instruction. 
 
Remote device station 
(station No. 2: 
occupies 2 stations)
Local station 
(station No.5: 
occupies 4 stations)
...The last 2 bits cannot be used when the master station and the local station are communicating.
Remote I/O station 
(station No. 1: 
occupies 1 station)
Master station
RX0F  to  RX00
RX1F  to  RX10
RX2F  to  RX20
RX3F  to  RX30
RX4F  to  RX40
RX5F  to  RX50
RX6F  to  RX60
RX7D  to  RX70
RX8F  to  RX80
RX9F  to  RX90
RXAF  to  RXA0
Remote input (RX)
RXBF  to  RXB0
RXCF  to  RXC0
RXDF  to  RXD0
RXEF  to  RXE0
RXFD  to  RXF0
RX10F  to  RX100
RX7FF  to  RX7F0
to
RY0F  to  RY00
RY1F  to  RY10
RY2F  to  RY20
RY3F  to  RY30
RY4F  to  RY40
RY5F  to  RY50
RY6F  to  RY60
RY7D  to  RY70
RY8F  to  RY80
RY9F  to  RY90
RYAF  to  RYA0
Remote output (RY)
RYBF  to  RYB0
RYCF  to  RYC0
RYDF  to  RYD0
RYEF  to  RYE0
RYFD  to  RYF0
RYAF  to  RYA0
RY7FF  to  RY7F0
to
RY0F  to  RY00
RY1F  to  RY10
RY2F  to  RY20
RY3F  to  RY30
RY4F  to  RY40
RY5F  to  RY50
RY6F  to  RY60
RY7D  to  RY70
RY8F  to  RY80
RY9F  to  RY90
RYAF  to  RYA0
Remote output (RY)
RYBF  to  RYB0
RYCF  to  RYC0
RYDF  to  RYD0
RYEF  to  RYE0
RYFD  to  RYF0
RYAF  to  RYA0
RY7FF  to  RY7F0
to
X0F  to  X00
X1F  to  X10
RX0F  to  RX00
RX1F  to  RX10
Remote input (RX)
Local station 
(station No.4: 
occupies 1 station)