Vidikron Vision Model 90t and Model 100t Owner’s Operating Manual
A-3 
 
Figure A-3. Vision 90t/100t Secondary RS-232 Port
4.
Connect the color sensor to any available COM or USB port. 
5.
Launch HyperTerminal. Open a connection using these parameters: 19200 baud, 8 data 
bits, no parity,1 stop bit and no flow control. 
6.
Press 
<Enter>
. The Vision 90t/100t responds with “+>” to indicate that it is ready to 
accept commands. 
7.
Start your color analyzer. Position the sensor approximately 6 to 12 inches from the 
screen, facing it at a slight angle (upward or to one side) so that the color of the screen is 
included in the calibration. 
A.3 
Serial Command Syntax
Table A-1 lists the serial command set for color gamut adjustments. The “Parameter 
(min/max)” column shows the valid parameter ranges, or “NA” for commands that take no 
parameters. 
When you enter a valid command, the Vision 90t/100t executes it and acknowledges it with a 
plus sign on the command line (+ >). When you enter an invalid command – one that is 
misspelled or followed by values outside the valid range for that command – the Vision 
90t/100t ignores it and returns a minus sign (- >).
Table A-1. Serial Commands for Gamut Adjustment 
Command
Parameter 
(min/max)
Value 
Stored?
Description
GAMUT WHITE
NA
NA
Displays white field on screen for 
measuring x and y coordinates; 
shows current x and y coordinates 
for white on the command line. 
GAMUT RED
NA
NA
Displays red field on screen for 
measuring x and y coordinates; 
shows current x and y coordinates 
for red on the command line.