Section 5 DLP-11 
Total Access 600 Series System Manual
 214
© 2004 ADTRAN, Inc.
61200624L1-1B
1. Connect to the Total Access 6XX using the CRAFT (RJ-48) port on the back of the Total Access 6XX.
If you are not already connected to the unit’s rear 
CRAFT
 interface, either with a VT100 compatible 
terminal or with a PC running VT100 emulation software, follow the procedure in DLP-1, Connecting a 
VT100 Terminal or PC to the CRAFT Port
. Connecting to the 
CRAFT
 interface limits the configuration 
transfer procedure to 
X
MODEM
 only.
2. Log in to the unit.
3. Go to the S
YSTEM
 U
TILITY
 menu and select C
ONFIGURATION
 T
RANSFER
 menu; press <Enter>.
4. Set the T
RANSFER
 M
ETHOD
 menu to X
MODEM
.
5. Select S
AVE
 C
ONFIG
 R
EMOTELY
 to start the transfers. Enter Y to confirm the transfer and prepare the 
Total Access 6XX for the transfer download. 
The following message is displayed: This will begin sending a copy of the current system 
configuration.
6. Configure the VT100 terminal or terminal emulation software to R
ECEIVE
 (and prompt for a filename).
7. View the C
URRENT
 T
RANSFER
 S
TATUS
 to verify the progress of the current transfer.
8. From the terminal emulation software, begin the XMODEM transfer by using the appropriate command 
sequence. For Windows HyperTerminal, select T
RANSFER
>R
ECEIVE
 F
ILE
. Enter the filename (including 
path) and select XMODEM as the transfer method.
If necessary, refer to the terminal emulation software documentation for help. 
Because XMODEM data is being transferred inband through the menu interface, the VT100 menus of 
the Total Access 6XX will be inoperable from the 
CRAFT 
interface. You can cancel the update at any 
time within the terminal emulation software. (Please consult the documentation provided by the 
terminal emulation software to determine how to do this.)
9. When the transfer has successfully completed, I
DLE
 displays in the C
URRENT
 T
RANSFER
 S
TATUS
 field 
and XMODEM D
OWNLOAD
 C
OMPLETE
 displays in the P
REVIOUS
 T
RANSFER
 S
TATUS
 field.
Perform the following steps in the order listed.
When specifying the filename, ensure that the saved file has a .cfg extension; 
otherwise, the file may not be available for uploading into other Total Access 6XX 
units.