6 Appendix 
129 
6.6   Appendix 6 
 
 
Connecting the system to PRI/T1 
 
Using CSU adapter 
 
Connecting the system to the 
ISDN network via the E1/T1-
interface using an Adtran T1 
ESF CSU ACE or equivalent 
CSU, will allow up to 1.54 Mbps 
connection. The E1/T1-interface 
must be connected to a CSU 
approved according to IEC 
60950, UL 1950 or equivalent 
standard. The PRI-line will run 
the AT&T 4ESS, 5ESS and 
National ISDN protocols in 
addition to Euro ISDN (E1). 
 
 
Connecting to Adtran T1 ESF CSU ACE 
 
Connect the PRI cable from the system to the input marked CPE (Customer Provided 
Equipment) on the Adtran CSU (straight through category 5 cable is recommended). Connect 
to the network via the NET connector on the Adtran CSU. When two systems are cascaded, 
connect the second system to the E1/T1 port 2 on the first system using a T1 crossover 
cable. 
 
Configuration of the system 
 
Open the Administrator Settings Menu from the Control Panel and select Network.  
Choose Network Type: PRI and specify your PRI number, max. Channels, cable length 
(between system and CSU) and switch type.   
 
Configuration of Adtran T1 ESF CSU ACE 
 

Enter 2)CONFIG menu using SCROLL and ENTER buttons. 

Enter 3)TERMINAL menu. Check 1)FORMAT:ESF, 2)CODE: B8ZS , 3)SET LBO: 0-
133 (corresponding to Cable Length setting on the system). 

Go to main menu and enter 1)NETWORK menu. 7)SET LBO: 0.0 (according to 
information from Telco). 

Also, other network parameters should be set according to information from your 
Telco. 
 
 
Note! Cascaded connection: Remember to program numbers and MSN. Otherwise, the 
first system will answer all calls.