Справочник Пользователя для Marantz PDxx01

Скачать
Страница из 49
PDxx01  
    RS-232C Control Specification 
Page: 32 / 49
Document Version [1.0]
 
 
Company Restricted 
 
 5-45. 
Failure Mode Request 
Function 
The external control equipment inquires the detection of failures of the plasma monitor. 
 
Transmission Data 
  1FH  80H  60H  3FH  00H  CKS 
ACK 
The plasma monitor returns the following ACK: 
  7FH  60H  80H  3FH  02H  DATA00  DATA01  CKS 
 
DATA00: FAILURE MODE 1 
 
Bit 0: PDP MODULE 
  
0: 
Abnormal 
  
 
1: 
Normal 
 
Bit 1: 1: fixed (backup) 
 Bit 
2: 
TEMPERATURE 
  
0: 
Abnormal 
  
 
1: 
Normal 
 
Bit 3: FAN 
  
0: 
Abnormal 
  
 
1: 
Normal 
 
Bit 4: TEMPERATURE SENSOR 
  
0: 
Abnormal 
  
 
1: 
Normal 
 
Bit 5: 1: fixed (backup) 
 
Bit 6: 1: fixed (backup) 
 
 
Bit 7:  1: fixed (backup) 
 
DATA01: FAILURE MODE 2 
 
Bit 0-7:    1: fixed (backup) 
 
 
Note: When 42 inch, “FAN” of DATA00-Bit3 is fixed “1”.