Справочник Пользователя для Panasonic ag-hpx300p

Скачать
Страница из 166
11
Chapter

Maintenance
and
Inspections
Warning System
Warning Description Tables
If a problem is detected immediately after the power is turned on, or during operation, this will be indicated by the 
WARNING lamp, lamps inside the viewfinder and a warning tone.
Priority
Warning 
type
LCD or viewfinder 
indication
Tally lamp
Warning 
lamp
Alarm 
tone
*6
Warning description 
and recording/playback 
operation
Countermeasures
1 System error
SYSTEM ERROR
Cause indication *
1
 Red 
blinking
Blinks 4 
times per 
second
Blinks 4 
times per 
second
Continuous 
tone
P2 microprocessor or control 
failure. Operation stops. 
Check the cause 
indication *
1
 and 
consult your 
distributor. 
2
Incorrect 
P2 card 
removal
TURN POWER OFF
Blinks red
Blinks 4 
times per 
second
Blinks 4 
times per 
second
Continuous 
tone
A P2 card was removed 
during access and card data 
was corrupted. 
Both access LEDs light 
orange.
Turn off the power. 
Repair the P2 card if 
the clips on the card 
are corrupted. 
3
The 
battery is 
exhauseted
LOW BATTERY Red 
blinking, and the battery 
level bar blinks with 
the empty status. (This 
indication appears also 
when MENU indications 
have been turned OFF.)
Blinks 1 time 
per second
Lights
Continuous 
tone
The battery is exhausted.
Recording and playback 
stop. The camera stops 
automatically when the 
voltage drops. 
Replace the battery. 
4
P2 card fully 
recorded
P2
 FULL
Blinks red (appears only for 
3 seconds in MCR mode.)
Blinks 4 
times per 
second after 
completion 
of recording. 
Lights after 
completing 
recording
Continuous 
tone after 
completing 
recording
No more space on P2 
cards left for recording.Stop 
recording.
*3
Delete clips that are 
no longer needed or 
insert a new card. 
5
Recording 
error
REC WARNING
Cause indication 
*2
 Blinks 
red
Blinks 4 
times per 
second
Blinks 4 
times per 
second
Intermittent 
tone 4 
times per 
second
A recording error has 
occurred. The error may 
terminate recording or let it 
continue.
 *4
Turn the power off 
and then back on 
again and check 
recording and 
playback. Replace 
any P2 card that 
does not enable 
normal recording. 
6
Irregular 
reference 
signal
TEMPORARY PAUSE 
IRREGULAR FRM SIG 
Blinks red.
Blinks 4 
times per 
second
Blinks 4 
times per 
second
Intermittent 
tone 4 
times per 
second
An irregular reference 
signal input to GENLOCK IN 
prevents normal recording 
by pausing recording. The 
recorded clip is divided.
•  Recording resumes when 
the signal returns to normal. 
Recording does not resume 
if interval, one-shot or loop 
recording is in progress.
Check the 
GENLOCK IN signal.
7
Drop in 
reception 
quality of 
wireless 
receiver 
transmission
WIRELESS RF  
Blinks red
Blinks 4 
times per 
second
(Recording 
only)
Blinks 4 
times per 
second
No
Indicates poor reception 
from the wireless receiver. 
Recording continues but 
wireless microphone cannot 
be received.
Check microphone 
power supply and 
receiver reception 
status.
(Continued on the next page)