Справочник Пользователя для Panasonic WJ-HD500A
68
The procedures described below let you set the parame-
ters for the Disk Recorder to communicate with external
devices.
ters for the Disk Recorder to communicate with external
devices.
1. Move the cursor to COMMUNICATION SETUP in the
WJ-HD500 SETUP menu by pressing the C or D but-
ton, then press the
ton, then press the
SET
button.
The COMMUNICATION SETUP menu shown below
appears on the monitor screen.
appears on the monitor screen.
2. Select an item or item parameter in the menu by press-
ing the D or C button.
3. To return to the previous WJ-HD500 SETUP menu,
press the
SETUP/ESC
button.
■
PS
•
Data Setup
These items let you set the parameters for communication
between the System Controllers and the Disk Recorders
when the system is controlled with the PS
between the System Controllers and the Disk Recorders
when the system is controlled with the PS
•
Data mode
(Panasonic Security Data).
1. Move the cursor to PS
•
Data SETUP in the COMMUNI-
CATION SETUP menu by pressing the C or D button,
then press the
then press the
SET
button.
The PS
•
Data SETUP menu shown below appears on
the monitor screen.
2. Select an item or item parameter in the menu by press-
ing the D or C button.
3. To return to the previous setup menu, press the
SETUP/ESC
button.
●
Unit Address Setting
This item lets you set the unit address of the Disk Recorder
in the system for RS-485 communication.
in the system for RS-485 communication.
1. Move the cursor to the UNIT ADDRESS parameter by
pressing the D or C button.
2. Select the unit address number to be used for RS-485
communication by pressing the + or - button.
Select a parameter value between 001 and 099.
Select a parameter value between 001 and 099.
The factory default setting is 001.
●
Baud Rate
This item lets you set the transmission speed for RS-485
communication.
communication.
1. Move the cursor to the BAUD RATE parameter by
pressing the D or C button.
2. Select the desired transmission speed shown below by
pressing the + or - button.
The factory default setting is 9 600 bps.
●
Data Bit
This item lets you set the number of data bits for RS-485
communication.
The factory default setting is 8 bits and fixed.
communication.
The factory default setting is 8 bits and fixed.
8 COMMUNICATION SETUP
PS•Data SETUP
RS232C SETUP
RS232C SETUP
NETWORK SETUP
IP ADDRESS 192.168.000.010
NETMASK 255.255.255.000
GATEWAY 192.168.000.001
IP ADDRESS 192.168.000.010
NETMASK 255.255.255.000
GATEWAY 192.168.000.001
8-1 PS•Data SETUP
UNIT ADDRESS 001
BAUD RATE 9600
DATA BIT 8
PARITY CHECK NONE
STOP BIT 1
WAIT TIME OFF
ALARM DATA 1S
BAUD RATE 9600
DATA BIT 8
PARITY CHECK NONE
STOP BIT 1
WAIT TIME OFF
ALARM DATA 1S
CAMERA NUMBER SETUP
↔
2 400
↔
4 800
↔
9 600
↔
19 200
↔
38 400
↔
COMMUNICATION SETUP